Home / Products / DC energy meter / PTB/ MID/Eichrecht DC Energy Meter for German Mess EV regulation

PTB/ MID/Eichrecht DC Energy Meter for German Mess EV regulation

  • PTB/ MID/Eichrecht DC Energy Meter for German Mess EV regulation
  • PTB/ MID/Eichrecht DC Energy Meter for German Mess EV regulation

DCM6-650

PTB/ MID/Eichrecht DC Energy Meter for German Mess EV regulation

  • Voltage up to 1000V
  • Max. current 650A
  • Charging Data recording
  • Charging Duration Monitoring
  • Signed and Encrypted Charging Data
  • Line loss energy measurement

DCM6-650 belongs to the DCM6 Series. It is a PTB(Eichrecht) and MID approved DC energy meter designed for measurement within an EV Charger station. The meter support Max. 650A current load. It has a dedicated micro-controller for encryption function in order to comply with Eichrecht, the German Mess-EV regulation. Furthermore, all charging processes are stored within the internal data storage of the DC meter. 

Another model in DCM6 Series is DCM6-200, which support Max. 200A current load.

Voltage
Umax 1000V DC
Umin 150V DC
Auxiliary power supply voltage 9-40V DC

 

Current
Ist (Starting current) 0.52A
Imin(Minimum current) 6.5A
Itr (Current) 13A
Iref (Normal current) 130A
Imax(Maximum current) 650A

 

Accuracy
Class 1

 

Display
LCD Dot Matrix
Life Cycle >12 Years

 

Serial Output
Type 2xRS485 (RTU)
Ports 2 xRJ12+1 plug-in terminal

 

RS485 interface
4800~115200bps(19200bps default) 8N1(Settable)

Wiring and Dimension [mm:]

Wiring and Dimension [mm:]

Wiring diagram

Wiring and Dimension [mm:]

Dimensions

Eastron Electronic Co., Ltd.

Eastron Electronic Co., Ltd. headquartered in Jiaxing, China, near to Shanghai, Hangzhou, Jiangsu, is one of the leading high-tech manufacturer and supplier for electricity products and energy measurement solutions. Over the years, we have developed a rich range of electricity meters, sensors, communication modules and management systems.Custom Manufacturers of PTB/ MID/Eichrecht DC Energy Meter for German Mess EV regulation.

Eastron keeps investing on the research and development of new technology and new products on electricity metering. We have energetic and innovative development teams in both China and UK,which help us keep the competitive edge in the market. The collaboration with leading universities and institutions also brings many cutting-edge technology into our products. To make sure the reliability of the products, Eastron has setup own professional lab that can performs EMC, LVD, accuracy and environment tests according to IEC, EN, GB, UL standards.

With more than 40 patented technologies on software, embedded software and hardware, Eastron has been awarded with “High-tech Enterprise” and “High-tech R&D Centre of Electricity Application”. Eastron strictly follows ISO 9001 Quality management system, and the production is approved by SGS according to MID standard.Suppliers and Factory of PTB/ MID/Eichrecht DC Energy Meter for German Mess EV regulation

Creating value to and growing up with our partners is our mission. Eastron provides not only the high quality and innovative products, but also first-class service to all our customers. We have professional team for technical supports and aftersales services. We have provided products and services to more than 50 countries in Europe, Asia-Pacific, America, Middle East, and Africa. We pride ourselves on having long-term partners globally that allows us to further our growth and bring our innovation and quality to the market.

Honor & Qualification

Choose comes from trust, and cooperation
comes from honesty.

NEWS

What are the best practices for protecting MID energy meters from cyberattacks or tampering?

Dec 23,2024

Physical Security MeasuresTamper-proof Enclosures: Use robus......

How do EV charger meters help in reducing energy waste in home charging systems?

Dec 18,2024

EV charger meters can significantly help in reducing energy ......

What are the energy efficiency advantages of using a 1000V DC energy meter in large-scale battery storage systems?

Dec 11,2024

Using a 1000V DC energy meter in large-scale battery storage......

How do EV charging meters handle overcharging protection and ensure the battery doesn’t receive excessive power?

Dec 05,2024

EV charging meters themselves don’t directly handle overchar......

How does a Single Phase ETL Energy Meter handle power surges or electrical faults?

Nov 21,2024

A Single Phase ETL Energy Meter is designed with certain pro......